Product Name : RG 3P
 
RG3P 3P 15A, 20A, 30A, 40A, 50A AC220V/380V Dual use 60Hz Rated sensitivity current : 30mA Operating time : High-speed type Rated short-time current
 
Unit Classification Supplementary Explanation
Unit Description
Enclosure Top cover, Base, Handle
Operating Mechanism Main housing, Spring, Pin, Screw
Terminals Outgoing copper, Incoming copper, Bare copper wire, Moving copper
Contacts Moving copper contact, Incoming copper contact
Circuit Board Circuit board, Electronic components, Electronic wire
Current Transformer Current transformer, Electronic wire
 
Packaging Cardboard Box
 
The status of restricted substance content for the product is disclosed on the website.
The ROHS information URL is marked on the packaging box.
The URL location is as follows: http://www.riken.com.tw/tw/pro.php?f=73&cid=123
Click on ROHS Substance Content Marking
 
Equipment Name: Residual Current Circuit Breaker (For Ground Fault Protection Only)
Model (Type): RG3P 50 Series models detailed on next page
 Unit
 
 Restricted Substances and their Chemical Symbols
Restircted substances and its chemical symbols    
 Lead (Pb)  Mercury (Hg)  Cadmium (Cd)
Hexavalent 
chromium (Cr+6)
Polybrominated
biphenyls 
(PBB)
Polybrominated
diphenyl  ethers
(PBDE)
 Enclosure  ○  ○  ○  ○  ○  ○
 Operating Mechanism  ○  ○  ○  ○  ○  ○
 Terminals  ○  ○  ○  ○  ○  ○
 Contacts  ○  ○  —  ○  ○  ○
 Circuit Board  ○  ○   ○  ○  ○  ○
 Current Transformer  ○  ○   ○  ○  ○  ○
 Note 1. “Exceeding 0.1 wt %” and “Exceeding 0.01 wt %” indicate that the percentage content of the restricted substance exceeds the reference percentage value of presence condition.
Note 2. “○” indicates that the percentage content of the restricted substance does not exceed the reference percentage value of presence.
Note 3. The “—” indicates that the restricted substance corresponds to an exemption.
 

 
Product Name: RG 30 2P (Rated Sensitivity Current 100MA)/ RG 30 2P (Rated Sensitivity Current 30MA)
 
RC30 2P 15A, 20A, 30A AC110V/220V Dual use 60Hz Rated sensitivity current : 100mA, 200mA, 300mA, Operating time : 
High-speed type Rated short-time current 1.5kA at AC110V/220V RG30 2P 15A, 20A, 30A, AC110V/220V Dual use 60Hz Rated
sensitivity current : 30mA Operating
time : High-speed type Rated short-time current 1.5kA at AC110V/220V
 
Unit Classification Supplementary Explanation
Unit Description
Enclosure Top cover, Base, Handle
Operating Mechanism Main housing, Spring, Pin, Screw, Arc extinguisher
Terminals Outgoing copper, Incoming copper, Bare copper wire, Moving copper
Contacts Moving copper contact, Incoming copper contact
Circuit Board Circuit board, Electronic components, Electronic wire
Current Transformer Current transformer, Electronic wire
 
Packaging Cardboard Box
 
The status of restricted substance content for the product is disclosed on the website.
The ROHS information URL is marked on the packaging box.
The URL location is as follows: http://www.riken.com.tw/tw/pro.php?f=73&cid=123
Click on ROHS Substance Content Marking 
 
Equipment Name: Residual Current Circuit Breaker
Model (Type): RG 30 2P (Rated Sensitivity Current 100MA)/ RG 30 2P (Rated Sensitivity Current 30MA) Series models detailed on next page
Model (Type): RG3P 50 Series models detailed on next page
 Unit
 
 Restricted Substances and their Chemical Symbols
Restircted substances and its chemical symbols    
 Lead (Pb)  Mercury (Hg)  Cadmium (Cd)
Hexavalent 
chromium (Cr+6)
Polybrominated
biphenyls 
(PBB)
Polybrominated
diphenyl  ethers
(PBDE)
 Enclosure  ○  ○  ○  ○  ○  ○
 Operating Mechanism  ○  ○  ○  ○  ○  ○
 Terminals  ○  ○  ○  ○  ○  ○
 Contacts  ○  ○  —  ○  ○  ○
 Circuit Board  ○  ○   ○  ○  ○  ○
 Current Transformer  ○  ○   ○  ○  ○  ○
 Note 1. “Exceeding 0.1 wt %” and “Exceeding 0.01 wt %” indicate that the percentage content of the restricted substance exceeds the reference percentage value of presence condition.. 
Note 2. “○” indicates that the percentage content of the restricted substance does not exceed the reference percentage value of presence.
Note 3. The “—” indicates that the restricted substance corresponds to an exemption.
 

 
Product Name: RG 50 2P
 
RG50 2P 15A, 20A, 30A, 40A, 50A AC110V/220V Dual use 60Hz Rated sensitivity current : 300mA,
Operating time : High-speed type Rated short-time current 2P 15A, 20A, 30A, 40A, 50A 2.5kA at  AC110V/220V 
 
Unit Classification Supplementary Explanation
Unit Description
Enclosure Top cover, Base, Handle
Operating Mechanism Main housing, Spring, Pin, Screw, Arc extinguisher
Terminals Outgoing copper, Incoming copper, Bare copper wire, Moving copper
Contacts Moving copper contact, Incoming copper contact
Circuit Board Circuit board, Electronic components, Electronic wire
Current Transformer Current transformer, Electronic wire
 
Packaging Cardboard Box
 
The status of restricted substance content for the product is disclosed on the website.
The ROHS information URL is marked on the packaging box.
The URL location is as follows: http://www.riken.com.tw/tw/pro.php?f=73&cid=123
Click on ROHS Substance Content Marking
 
Equipment Name: Residual Current Circuit Breaker, Model (Type): RG-50 2P Series models detailed on next page
Equipment name       Type designation(Type)
 Unit
 
 Restricted Substances and their Chemical Symbols
Restircted substances and its chemical symbols    
 Lead (Pb)  Mercury (Hg)  Cadmium (Cd)
Hexavalent 
chromium (Cr+6)
Polybrominated
biphenyls 
(PBB)
Polybrominated
diphenyl  ethers
(PBDE)
 Enclosure  ○  ○  ○  ○  ○  ○
 Operating Mechanism  ○  ○  ○  ○  ○  ○
 Terminals  ○  ○  ○  ○  ○  ○
 Contacts  ○  ○  —  ○  ○  ○
 Circuit Board  ○  ○   ○  ○  ○  ○
 Current Transformer  ○  ○   ○  ○  ○  ○
 Note 1. “Exceeding 0.1 wt %” and “Exceeding 0.01 wt %” indicate that the percentage content of the restricted substance exceeds the reference percentage value of presence condition.
Note 2. “○” indicates that the percentage content of the restricted substance does not exceed the reference percentage value of presence.
Note 3. The “—” indicates that the restricted substance corresponds to an exemption.
 

 
Product Name : RK-100EB 100AF 3P
 
RK-100EB 100AF 3P 15A, 20A, 30A, 40A, 50A, 60A, 75A, 100A 60Hz Icu=15kA, Ics=8kA, 220V, Icu=10kA, 
 
Unit Classification Supplementary Explanation
Unit Description
Enclosure Top cover, Base, Handle
Operating Mechanism Main housing, Spring, Pin, Screw, Arc extinguisher
Terminals Outgoing copper, Incoming copper, Bare copper wire, Moving copper, Alloy piece
Contacts Moving copper contact, Incoming copper contact
 
Packaging Cardboard Box
 
The status of restricted substance content for the product is disclosed on the website.
The ROHS information URL is marked on the packaging box.
The URL location is as follows: http://www.riken.com.tw/tw/pro.php?f=73&cid=123
Click on ROHS Substance Content Marking 
 
Equipment Name: Molded Case Circuit Breaker, Model (Type): RK-100EB 100AF 3P Series models detailed on next page
Equipment name       Type designation(Type)
 Unit
 
 Restricted Substances and their Chemical Symbols
Restircted substances and its chemical symbols    
 Lead (Pb)  Mercury (Hg)  Cadmium (Cd)
Hexavalent 
chromium (Cr+6)
Polybrominated
biphenyls 
(PBB)
Polybrominated
diphenyl  ethers
(PBDE)
 Enclosure  ○  ○  ○  ○  ○  ○
 Operating Mechanism  ○  ○  ○  ○  ○  ○
 Terminals  ○  ○  ○  ○  ○  ○
 Contacts  ○  ○  —  ○  ○  ○
 Note 1. “Exceeding 0.1 wt %” and “Exceeding 0.01 wt %” indicate that the percentage content of the restricted substance exceeds the reference percentage value of presence condition.
Note 2. “○” indicates that the percentage content of the restricted substance does not exceed the reference percentage value of presence.
Note 3. The “—” indicates that the restricted substance corresponds to an exemption.
 

 
Product Name: 100SB 100AF 3P
 
Main Type : 100SB 100AF 3P 15A, 20A, 30A, 40A, 50A, 60A, 75A, 100A
50/60Hz Icu=25kA, Ics=13kA, at 220V
 
Unit Classification Supplementary Explanation
Unit Description
Enclosure Top cover, Base, Handle
Operating Mechanism Main housing, Spring, Pin, Screw, Arc extinguisher
Terminals Outgoing copper, Incoming copper, Bare copper wire, Moving copper, Silicone tube
Contacts Moving copper contact, Incoming copper contact
 
Packaging Cardboard Box
 
The status of restricted substance content for the product is disclosed on the website.
The ROHS information URL is marked on the packaging box.
The URL location is as follows: http://www.riken.com.tw/tw/pro.php?f=73&cid=123
Click on ROHS Substance Content Marking
 
Equipment Name: Molded Case Circuit Breaker, Model (Type): 100SB 100AF 3P Series models detailed on next page
Equipment name       Type designation(Type)
 Unit
 
 Restricted Substances and their Chemical Symbols
Restircted substances and its chemical symbols    
 Lead (Pb)  Mercury (Hg)  Cadmium (Cd)
Hexavalent 
chromium (Cr+6)
Polybrominated
biphenyls 
(PBB)
Polybrominated
diphenyl  ethers
(PBDE)
 Enclosure  ○  ○  ○  ○  ○  ○
 Operating Mechanism  ○  ○  ○  ○  ○  ○
 Terminals  ○  ○  ○  ○  ○  ○
 Contacts  ○  ○  —  ○  ○  ○
 Note 1. “Exceeding 0.1 wt %” and “Exceeding 0.01 wt %” indicate that the percentage content of the restricted substance exceeds the reference percentage value of presence condition.
Note 2. “○” indicates that the percentage content of the restricted substance does not exceed the reference percentage value of presence.
Note 3. The “—” indicates that the restricted substance corresponds to an exemption.
 

 
 
Product Name : SRG 2P
 
SRG 2P 15A, 20A, 30A AC110V~220V Dual use 60Hz Rated sensitivity current : 30mA, /100/200/300mA
(Fixed type) Operating time : High-speed type Rated short-time current 1.5kA at AC110V, 220V (Surge-proof type)
 
Unit Classification Supplementary Explanation
Unit Description
Enclosure Top cover, Base, Handle
Operating Mechanism Main housing, Spring, Pin, Screw, Arc extinguisher
Terminals Outgoing copper, Incoming copper, Bare copper wire, Moving copper, Silicone tube
Contacts Moving copper contact, Incoming copper contact
Circuit Board Circuit board, Electronic components, Electronic wire
Current Transformer Current transformer, Electronic wire
 
Packaging Cardboard Box

The status of restricted substance content for the product is disclosed on the website.

The ROHS information URL is marked on the packaging box.
The URL location is as follows: http://www.riken.com.tw/tw/pro.php?f=73&cid=123
Click on ROHS Substance Content Marking
 
Equipment Name: Residual Current Circuit Breaker, Model (Type): SRG 2P Series models detailed on next page
Equipment name       Type designation(Type)
 Unit
 
 Restricted Substances and their Chemical Symbols
Restircted substances and its chemical symbols    
 Lead (Pb)  Mercury (Hg)  Cadmium (Cd)
Hexavalent 
chromium (Cr+6)
Polybrominated
biphenyls 
(PBB)
Polybrominated
diphenyl  ethers
(PBDE)
 Enclosure  ○  ○  ○  ○  ○  ○
 Operating Mechanism  ○  ○  ○  ○  ○  ○
 Terminals  ○  ○  ○  ○  ○  ○
 Contacts  ○  ○  —  ○  ○  ○
 Note 1. “Exceeding 0.1 wt %” and “Exceeding 0.01 wt %” indicate that the percentage content of the restricted substance exceeds the reference percentage value of presence condition.
Note 2. “○” indicates that the percentage content of the restricted substance does not exceed the reference percentage value of presence.
Note 3. The “—” indicates that the restricted substance corresponds to an exemption.
 

 
 
Product Name : SRG- 2P
 
SRG-50 2P 15A, 20A, 30A, 40A, 50A AC110V/220V Dual use 60Hz Rated sensitivity
current : 30mA, Operating time : High-speed type  Rated short-time current : 15A, 20A, 30A
 
Unit Classification Supplementary Explanation
Unit Description
Enclosure Top cover, Base, Handle
Operating Mechanism Main housing, Spring, Pin, Screw, Arc extinguisher
Terminals Outgoing copper, Incoming copper, Bare copper wire, Moving copper
Contacts Moving copper contact, Incoming copper contact
Circuit Board Circuit board, Electronic components, Electronic wire
Current Transformer Current transformer, Electronic wire
 
Packaging Cardboard Box
 
 
The status of restricted substance content for the product is disclosed on the website.
The ROHS information URL is marked on the packaging box.
The URL location is as follows: http://www.riken.com.tw/tw/pro.php?f=73&cid=123
Click on ROHS Substance Content Marking
 
Equipment Name: Residual Current Circuit Breaker, Model (Type): SRG-50 2P Series models detailed on next page
Equipment name       Type designation(Type)
 Unit
 
 Restricted Substances and their Chemical Symbols
Restircted substances and its chemical symbols    
 Lead (Pb)  Mercury (Hg)  Cadmium (Cd)
Hexavalent 
chromium (Cr+6)
Polybrominated
biphenyls 
(PBB)
Polybrominated
diphenyl  ethers
(PBDE)
 Enclosure  ○  ○  ○  ○  ○  ○
 Operating Mechanism  ○  ○  ○  ○  ○  ○
 Terminals  ○  ○  ○  ○  ○  ○
 Contacts  ○  ○  —  ○  ○  ○
 Circuit Board  ○  ○  ○  ○  ○  ○
 Current Transformer  ○  ○  ○  ○  ○  ○
 Note 1. “Exceeding 0.1 wt %” and “Exceeding 0.01 wt %” indicate that the percentage content of the restricted substance exceeds the reference percentage value of presence condition.
Note 2. “○” indicates that the percentage content of the restricted substance does not exceed the reference percentage value of presence.
Note 3. The “—” indicates that the restricted substance corresponds to an exemption.

Product Inquiry

Related Products


BH MCB BH MCB
detail
EL protection socket EL protection socket
detail
ELCB ELCB
detail
RoHS Restricted Substances Content Marking (I) RoHS Restricted Substances Content Marking (I)
detail
RoHS Restricted Substances Content Marking (II) RoHS Restricted Substances Content Marking (II)
detail